encoder interface unit - Hany Ferdinando - Oct 21 8:30:00 2003



Hi all,

I used 2199x Encoder Interface Unit to estimate the velocity of motor shaft. My
idea is I generate 1ms interval of interrupt (using EIU loop timer) and read
the counter value then reset it. I got strange result when I tried to calibrate
the value. According to the manual, the value read from the register is 4 times
the value from the encoder.

Anyone has an idea about this phenomena?

regards,
Hany





(You need to be a member of adsp -- send a blank email to adsp-subscribe@yahoogroups.com )

Re: encoder interface unit - Steve Holle - Oct 21 14:28:00 2003

What they are saying, I think, is that the EIU counts the rising and falling edges of the Phase A and B signals.  If you have a 128 cycle encoder you will actually read 512 counts per revolution.

At 02:30 AM 10/21/2003, Hany Ferdinando wrote:
Hi all,

I used 2199x Encoder Interface Unit to estimate the velocity of motor shaft. My
idea is I generate 1ms interval of interrupt (using EIU loop timer) and read
the counter value then reset it. I got strange result when I tried to calibrate
the value. According to the manual, the value read from the register is 4 times
the value from the encoder.

Anyone has an idea about this phenomena?

regards,
Hany _____________________________________
/groups.php3
 

--------------------------
Steve Holle
Link Communications, Inc.
1035 Cerise Road
Billings, Montana  59101-7378
406.245.5002
s...@link-comm.com
--------------------------