Technical discussions related to Analog Devices DSPs (including Blackfin, TigerSHARC, SHARC and ADSP-21xx DSPs).
|
Hi all, I used 2199x Encoder Interface Unit to estimate the velocity of motor shaft. My idea is I generate 1ms interval of interrupt (using EIU loop timer) and read the counter value then reset it. I got strange result when I tried to calibrate the value. According to the manual, the value read from the register is 4 times the value from the encoder. Anyone has an idea about this phenomena? regards, Hany |
|
|
|
What they are saying, I think, is that the EIU counts the rising and
falling edges of the Phase A and B signals. If you have a 128 cycle
encoder you will actually read 512 counts per revolution. At 02:30 AM 10/21/2003, Hany Ferdinando wrote: Hi all, Steve Holle Link Communications, Inc. 1035 Cerise Road Billings, Montana 59101-7378 406.245.5002 s...@link-comm.com -------------------------- |