Clock Speed Problem? - Roy Closa - Nov 6 2:26:00 2002



Hello everybody!!

I have tried to initialize my TMS320C542 in a
100-Mhz Pentium I and selftest.exe is successful.
However, I tried to initialize other TMS320C542's
(3 kits in all) in a Pentium II and Pentium III PC's
the selftest.exe (under c:\dskplus) responded with: Attempting 8-bit Data I/O . . . .
8-bit Mode is Functional

No response from HINT interrupt signal.

* * * * TEST FAILED * * * * I have tried the change the I/O configurations among
Normal, EPP, ECP and EPP+ECP but to no avail.

Is it really so that TMS320C5xx and TMS320C54xx DSP
kits can run only on Pentium I platform? or is there
a way to overcome this problem.

I hope somebody in the group can answer this problem.
Thank you!!






(You need to be a member of c54x -- send a blank email to c54x-subscribe@yahoogroups.com )

Re: Clock Speed Problem? - R. Stephen L. Ruiz - Nov 7 5:08:00 2002

Mabuhay! Roy,

Selftest polls HINT to check dsp-to-pc interrupt. The poll duration could be
too short in a Pentium II or III. Try increasing the duration by modifying
HINT(duration)
in line 190 of selftest.cpp (\dskplus\source) and recompile.

Hope this helps.

Stephen

----- Original Message -----
From: "Roy Closa" <>
To: <>
Sent: Wednesday, November 06, 2002 10:26 AM
Subject: [c54x] Clock Speed Problem? > Hello everybody!!
>
> I have tried to initialize my TMS320C542 in a
> 100-Mhz Pentium I and selftest.exe is successful.
> However, I tried to initialize other TMS320C542's
> (3 kits in all) in a Pentium II and Pentium III PC's
> the selftest.exe (under c:\dskplus) responded with: > Attempting 8-bit Data I/O . . . .
> 8-bit Mode is Functional
>
> No response from HINT interrupt signal.
>
> * * * * TEST FAILED * * * * > I have tried the change the I/O configurations among
> Normal, EPP, ECP and EPP+ECP but to no avail.
>
> Is it really so that TMS320C5xx and TMS320C54xx DSP
> kits can run only on Pentium I platform? or is there
> a way to overcome this problem.
>
> I hope somebody in the group can answer this problem.
> Thank you!! >
>
> _____________________________________




(You need to be a member of c54x -- send a blank email to c54x-subscribe@yahoogroups.com )