AD535 | BIOS | Booting | Bootloader | C621 | C6211 | C6415 | C671 | C6711 | C6711DSK | C6713 | CCS | Chassaing | COFF | DAT | DM64 | DM642 | DMA | DSK671 | DSK6711 | EDM | EDMA | EMIF | Emulator | EVM | EVM620 | FFT | FIR | GPIO | Halting | HPI | HWI | IDK | JTAG | LDB | LDH | LDW | Linker | LMS | LOG_printf | Matlab | McBSP | MEM_alloc | MIPS | PCI | PCM3003 | Pipeline | Profiling | QDM | Reset | ROM | RTDX | Sampling | SDRAM | Stack | TEB | THS1206 | TMS320C621 | TMS320C6416 | TMS320C6711 | TMS320C6713 | UART | Vector Table | XBUS | XDS560

Ads

Discussion Groups

Discussion Groups | TMS320C6x | C6416 TEB Schematics

Technical discussions about the TI C6000 DSPs (including the c62x, c64x and c67x DSPs).

  

Post a new Thread

C6416 TEB Schematics - Kevin Howson - Jan 27 15:57:00 2003



Hi All,

Does anyone out there have any experience with the GPIO lines of the C6416 TEB?
We have a customer trying to put a probe onto those lines and they need to know
where they are available on the board. Unfortunately the only schematics I have
do not load properly, which means that you cannot see all the sheets.

From what I have been able to see I believe that GP4 - GP7 (DC_EINT4 to
DC_EINT7) are available on the External Peripheral Interface (J1) as follows:

DC_EINT4 ==> J1 - 53
DC_EINT5 ==> J1 - 48
DC_EINT6 ==> J1 - 67
DC_EINT7 ==> J1 - 68

Does anyone have a set of schematics for the C6416 TEB that open properly (I am
using Acrobat Reader 5.0.5). Failing that does anyone have the locations of the
other GPIO pins on the daughtercard interface?

Thanks in advance for any help.

Kevin Howson
Technical Manager
Kane Computing Ltd






(You need to be a member of c6x -- send a blank email to c6x-subscribe@yahoogroups.com )

PIPELINE STALL IN CCS. - mohammed samdani - Jan 28 11:49:00 2003

hi,
I am fine, hoping the same with you too.

I want to know what is pipeline stall.( when we open
CCS on the menu column there is profiler, under which
is present clock setup … under this there is count
dropdown menu in which is present pipeline stall)

When I enable clock for pipeline stall I want to know
what information the pipeline stall count will give.

When I run the program using F5 having enabled the
clock for pipeline stall I get 17520 count

But when I run the program using only F8 (single step
) having enabled the clock for pipeline stall I get
zero(0) count. I would like to know why.

Thanking you

MOS.