56303 | 563xx | 5680 | 56805 | 5680x | 56F80 | 56F800DEMO | 56F805 | 56f807 | 56F830 | ADC | Bootloader | Codec | CodeWarrior | CW5 | CW6 | Debugger | DSP56303 | DSP56303EVM | DSP563xx | DSP5680 | DSP56800 | DSP56807 | DSP56858 | DSP56858EVM | DSP56F803 | DSP56F805 | DSP56F807 | DSP56F80x | DSP56F826 | DSP56F827 | DSP56F8xx | EVM | FFT | Flash_over_jtag | GPIO | Interrupt | Interrupts | JTAG | LCD | Linker | MCF5307 | Metrowerks | Modulus | MSCAN | PCMaster | PWM | Quad | Rif | RTOS | SDK | SPI

Discussion Groups

Discussion Groups | Freescale DSPs | DSP56F807 PWM Automatic Fault Clearing

Technical discussions about Freescale (Motorola) DSPs (including the DSP56000, DSP56300, DSP56600, 56800 DSPs).

  

Post a new Thread

DSP56F807 PWM Automatic Fault Clearing - frankbertling - Feb 7 9:13:00 2003



Dear All,

In contradiction to the behaviour described in the Userīs Manual
(DSP56F801-7UM/D - Rev. 3.0, Chapter 11.5.8.2), we observe PWM
outputs being re-enabled within a PWM cycle as soon as the Fault
input (configured for automatic fault clearing) returns to zero.

The Chip Errata (DSP56F807E/D Rev. 9.0, 1/2003, Page 5) states that
this is a problem of Revision D DSP56F807 devices. Will there be a
new revision that solves this issue? Regards,
Frank Bertling