AW: Can one use CW5.1 and CW6.1 on same computer?

Started by Bende Georg in Freescale DSPs15 years ago

I have CW5.0, CW5.1 and CW6.0 working parallel without probs. Georg Bende Softwareentwickler Abteilung Elektronik Dr. Fritz...

I have CW5.0, CW5.1 and CW6.0 working parallel without probs. Georg Bende Softwareentwickler Abteilung Elektronik Dr. Fritz Faulhaber GmbH & Co KG Daimlerstr. 23 71101 Sch?naich Tel: +49 7031 638294 > -----Urspr?ngliche Nachricht---


Can one use CW5.1 and CW6.1 on same computer?

Started by Pete Becher in Freescale DSPs15 years ago 1 reply

Hi All, Just wondering if CW5.1 and CW6.1 for 56F8XXx can coexist on the same computer without any problems. Is anyone using it...

Hi All, Just wondering if CW5.1 and CW6.1 for 56F8XXx can coexist on the same computer without any problems. Is anyone using it that way? I am just afraid of having way too many problems if I just upgrade to 6.1 and overwrite 5.1. Thanks, Pete


Interrupt/context problem?

Started by Jarrid Gross in Freescale DSPs17 years ago 14 replies

I have been having some tough problems all along, and had hoped that upgrading to CW5.0 + 5.02 patch would cure me, but it didnt... ...

I have been having some tough problems all along, and had hoped that upgrading to CW5.0 + 5.02 patch would cure me, but it didnt... Heres what happens. uint32 bogie_call(float * flt_arg_ptr, uint32 long_arg) { float f; f = 100; //


Flash application without ext memory for DSP56F803

Started by Krzysztof Gruszka in Freescale DSPs17 years ago 1 reply

Hello, please be so kind and help me. I am newbie in CodeWarrior and I need to program DSP56F803 as single chip without...

Hello, please be so kind and help me. I am newbie in CodeWarrior and I need to program DSP56F803 as single chip without external memory. I can't find correct way how to setup CW5.0 for such type of application. Can you send me some example? Best regards Krzysztof


Multiple ADC / 805 / SDK2.5 / CW5 question

Started by chaderry in Freescale DSPs16 years ago

First off - I apologize if this message reaches some of you twice; I tried two days ago to post by email and yahoo - for the same...

First off - I apologize if this message reaches some of you twice; I tried two days ago to post by email and yahoo - for the same reason it refuses to accept even the passwords it's assigned me for my real account (forcing me to moonlight as charles derry, my spam attack addre


DSP56807, CW6.1 stack problem

Started by t_karin1 in Freescale DSPs15 years ago

I am working on DSP56807, with SDK2.5 with uCOS-II RTOS. till now I was working with CW5.1 and everything was great. However I...

I am working on DSP56807, with SDK2.5 with uCOS-II RTOS. till now I was working with CW5.1 and everything was great. However I recently switched to CW6.1 and since then I can not see the Stack window properly, instead of showing me the order of the function calls, it shows me


CW5.1 Predefined Macro for Target Board

Started by kj831ca in Freescale DSPs16 years ago 1 reply

Hi, Does anybody know if there is a predefined macro that would allow me to know which target board is being used in the...

Hi, Does anybody know if there is a predefined macro that would allow me to know which target board is being used in the project? I'm trying to write my own on-chip portable code for both DSP56F805 and DSP56F807 something like as belows : #if (TARGET = DSP56F805)


strange var assignments in CW5.0.4 w/sdk 2.5 - dsp56807

Started by vagenta in Freescale DSPs16 years ago

I am having very odd variable assigments when using the debugger. Multipart question: 1. First with #defines. In order to...

I am having very odd variable assigments when using the debugger. Multipart question: 1. First with #defines. In order to access a direct memory location on the external data memory space say at $C008 and $C00A, in order for our external logic to interpret the data, we h


56800e Inline assembler and inline functions

Started by jack...@motec.com.au in Freescale DSPs14 years ago

Hi, I have a couple of questions about inline assembler and inline functions in the 56800E compiler under CW5.6 Question 1: Is there anyway...

Hi, I have a couple of questions about inline assembler and inline functions in the 56800E compiler under CW5.6 Question 1: Is there anyway to use members of a C struct in the assembler code? I can use local or static variables in assembler functions eg. int32 myVar; asm { move.l myVar,A } but is there a way to use a pointer to a struct to access st