danisade,
from your description, I suspect the PC ran out of heap or virtual memory or
RAM.
What is being done with those messages after they are received by the PC?
Is the DSK waiting for the PC to complete processing (what is the processing) of
a message before
sending the next message?
R. Williams
---------- Original Message -----------
From: "danisade"
To: c...
Sent: Sun, 06 Jul 2008 09:01:10 -0000
Subject: [c6x] hsrtdx with xds560r
> after send about 500 messeges of 250 integers i have
sucess with
> dsk6713
> but if i try to send 2000 messeges of 250 the code composer 3.1
> stucks any one know why >?
>
> ----------
> this is the messege
> --------------
> Failed Software Reset: Error 0x00000020/-2211 Error during:
> Execution, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 16 Error Code: -2211 Error Class: 0x00000020
> Trouble Reading PC Register: Error 0x00000004/-2211 Error during:
> Register, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 5 Error Code: -2211 Error Class: 0x00000004
> Trouble Reading Register: Error 0x00000004/-2211 Error during:
> Register, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 5 Error Code: -2211 Error Class: 0x00000004
> Trouble Reading PC Register: Error 0x00000004/-2211 Error during:
> Register, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 5 Error Code: -2211 Error Class: 0x00000004
> Trouble Reading FP Register: Error 0x00000004/-2211 Error during:
> Register, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 5 Error Code: -2211 Error Class: 0x00000004
> Trouble Reading Register: Error 0x00000004/-2211 Error during:
> Register, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 5 Error Code: -2211 Error Class: 0x00000004
> Trouble Reading PC Register: Error 0x00000004/-2211 Error during:
> Register, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 5 Error Code: -2211 Error Class: 0x00000004
> Trouble Reading FP Register: Error 0x00000004/-2211 Error during:
> Register, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 5 Error Code: -2211 Error Class: 0x00000004
> Error: Error 0x00000020/-2211 Error during: Execution,
> TRG_ERR_COMM_FAILURE Error Occured at 0x00000000 Sequence ID: 16
> Error Code: -2211 Error Class: 0x00000020
> Trouble Halting Target CPU: Error 0x00000020/-2211 Error during:
> Execution, TRG_ERR_COMM_FAILURE Error Occured at 0x00000000
> Sequence ID: 15 Error Code: -2211 Error Class: 0x00000020
> -----------------------------
>
> the same project works with blackhawk lan560 and i can send even
> 10000 messeges of 250 integers without trouble
------- End of Original Message -------