Hello ehng3, Friday, May 14, 2004, 1:25:25 PM, you wrote: The problem most probably lies in the fact that you make a jump to a location in CEx from IRAM with near call model enabled in the compiler settings. Please try to change the call model to far in the compiler settings tab - try setting it as 'far calls & data '. Also, if you are writing in assembly, do not use branches like b .s2 _label because this sort of branch does not support 32-bit offsets, as far as I remember. The good way to do it is mvkl .s2 _label, b0 mvkh .s2 _label, b0 b .s2 b0 I think this should solve the problem. Best regards, Michael Kapralov e> Hi, e> Does AnyOne Know How to Sovle This Error? I am Using C6711 With e> PCM3003. e> Is't the problem due to the setting of cmd file or option? e> ....... >>> error: relocation overflow occured at address 0x000003a8 in e> section '.text' >>> error: relocation overflow occured at address 0x000003ec in e> section '.text' >>> error: relocation overflow occured at address 0x000004e4 in e> section '.text' >>> error: relocation value truncated at 0x1ac in section .text, file >>> warning: output file SDF.out not executable e> Thanks e> Regards e> Eng Hsiung e> _____________________________________ e> Note: If you do a simple "reply" with your email client, only the author of this message will receive your answer. You need to do a "reply all" if you want your answer to be distributed to the e> entire group. e> _____________________________________ e> About this discussion group: e> To Join: Send an email to e> To Post: Send an email to e> To Leave: Send an email to e> Archives: http://www.yahoogroups.com/group/c6x e> Other Groups: http://www.dsprelated.com e> Yahoo! Groups Links -- Best regards, Michael mailto: |