Reply by Bill Finger September 16, 20082008-09-16
Hugo,

How do you know you've started the timer if you never see it increment?
What values are you setting the control registers to?

Some simple code:

// Reset timer:
*T0_ctrl = 0;

// Setup timer function as external counter:
*T0_ctrl = C3X_TIMER_CLKSRC_EXT | C3X_TIMER_FUNC_TIMER;

// Reset counter and period register:
*T0_prd = -1; // maximum value so no overflow.
*T0_count = 0;

// Start counter:
*T0_ctrl |= C3X_TIMER_GO | C3X_TIMER_NHLD;
where

#define C3X_TIMER_TSTAT 0x00000800
#define C3X_TIMER_INV 0x00000400
#define C3X_TIMER_CLKSRC_INT 0x00000200
#define C3X_TIMER_CLKSRC_EXT 0x00000000
#define C3X_TIMER_C_NP 0x00000100
#define C3X_TIMER_NHLD 0x00000080
#define C3X_TIMER_GO 0x00000040
#define C3X_TIMER_DATIN 0x00000008
#define C3X_TIMER_DATOUT 0x00000004
#define C3X_TIMER_NI_O 0x00000002
#define C3X_TIMER_FUNC_TIMER 0x00000001
#define C3X_TIMER_FUNC_IO 0x00000000

and

#define T0_ctrl ((volatile unsigned long *) 0x808020L) /* TIM0 gl
control */
#define T0_count ((volatile unsigned long *) 0x808024L) /* TIM0 count
*/
#define T0_prd ((volatile unsigned long *) 0x808028L) /* TIM0 prd
*/
Hope this helps.
Bill

> -----Original Message-----
> From: c... [mailto:c...] On
> Behalf Of Brunert, Hugo (US SSA)
> Sent: Tuesday, September 16, 2008 8:56 AM
> To: c...
> Subject: [c3x] Timer counters
>
> Hello,
>
>
>
> First of all, I am at work, and we cannot have yahoo messenger on, so
> please do not try to reach me via IM.
>
> Thank you
>
>
>
> Now the real problem, I have a C31 with 2 timers and they are
> mapped as
> such:
>
> // Memory Mapped Registers
>
>
>
> #define TIMER_0_CONTROL 0x00808020 // Timer 0 Global Control
>
> #define TIMER_0_COUNTER 0x00808024 // Timer 0 Counter
>
> #define TIMER_0_PERIOD 0x00808028 // Timer 0 Period
>
>
>
> #define TIMER_1_CONTROL 0x00808030 // Timer 1 Global Control
>
> #define TIMER_1_COUNTER 0x00808034 // Timer 1 Counter
>
> #define TIMER_1_PERIOD 0x00808038 // Timer 1 Period
>
>
>
> I have been able to set the period on both timers and I have been able
> to start both timers.
>
> However I have not been able to read the counter register.
>
> I assume it is a 32 bit word, which gets set to 0 when you start the
> timer, and it increments by one on every tic of the timer.
>
> Is this assumption correct?
>
> If so, I get 0 all the time, I never see it increment.
>
> What am I doing wrong.
>
> All I'm doing is reading the unsigned long int at location 0x00808034
> and storing it in a local array of unsigned long ints.
>
>
>
> Thank you for the help.
>
>
>
> Hugo Brunert
>
> Software Engineering
>
> BAE Systems
>
> Electronic & Integrated Solutions
>
> Sensor Systems, Identification & Surveillance
>
> MS 1-12
>
> 1 Hazeltine Way
>
> Greenlawn, NY 11740-1606
>
> Voice: (631)912-2885
>
> Fax: (631)912-2909
>
> Email: H...@BAESystems.com
>
Reply by "Brunert, Hugo (US SSA)" September 16, 20082008-09-16
Hello,

First of all, I am at work, and we cannot have yahoo messenger on, so
please do not try to reach me via IM.

Thank you

Now the real problem, I have a C31 with 2 timers and they are mapped as
such:

// Memory Mapped Registers

#define TIMER_0_CONTROL 0x00808020 // Timer 0 Global Control

#define TIMER_0_COUNTER 0x00808024 // Timer 0 Counter

#define TIMER_0_PERIOD 0x00808028 // Timer 0 Period

#define TIMER_1_CONTROL 0x00808030 // Timer 1 Global Control

#define TIMER_1_COUNTER 0x00808034 // Timer 1 Counter

#define TIMER_1_PERIOD 0x00808038 // Timer 1 Period

I have been able to set the period on both timers and I have been able
to start both timers.

However I have not been able to read the counter register.

I assume it is a 32 bit word, which gets set to 0 when you start the
timer, and it increments by one on every tic of the timer.

Is this assumption correct?

If so, I get 0 all the time, I never see it increment.

What am I doing wrong.

All I'm doing is reading the unsigned long int at location 0x00808034
and storing it in a local array of unsigned long ints.

Thank you for the help.

Hugo Brunert

Software Engineering

BAE Systems

Electronic & Integrated Solutions

Sensor Systems, Identification & Surveillance

MS 1-12

1 Hazeltine Way

Greenlawn, NY 11740-1606

Voice: (631)912-2885

Fax: (631)912-2909

Email: H...@BAESystems.com