Reply by January 31, 20022002-01-31


Perry,

    We have verified that what you have found is correct,
this is a bug in the CSL.  We'll put this in our next release of CSL.  

     We further apologize for any inconvenience this bug has caused.  

   Thank you for bringing it to our attention. REGARDS,
DSP Hotline

If you need further assistance, you may contact us at:

    EMAIL:              s...@ti.com
    Online Assistance:  www.dspvillage.com
    Phone:              972-644-5580

------------------
Note: In the event that information received from the
TI TMS320 DSP Technical Support Hotline conflicts with
TI supplied or originated written documentation, that
information from TI supplied or originated written
documentation should be used. -----Original Message-----
To: s...@ti.com
Date: Wed, 30 Jan 2002 09:15:44 -0600
From: p...@telex.com
Subject: SYSR address

 /******************************************************************************\
 * _C
HIP_SYSR - System Control Register
 *
 * Fields:
 *   (RW) _CHIP_SYSR_HPE
 *   (RW) _CHIP_SYSR_BH
 *   (RW) _CHIP_SYSR_HBH
 *   (R)  _CHIP_SYSR_BOOTM3
 *   (RW) _CHIP_SYSR_CLKDIV
 *

\******************************************************************************/
 #define _CHIP_SYSR_ADDR       (0x03FDu)
 #define _CHIP_SYSR             REG16(_CHIP_SYSR_ADDR)
 #define _SYSR                 _SYSR The define address is ?????? correct, incorrect? I'm writing to 0x07FD and
it works, please note this issue.

Perry Howell
Lead Design Engineer
Vega Signaling Products
Telex Communications, Inc
8601 East Cornhusker Hiway
Lincoln NE, 68507-9702
402-465-6621
402-467-4003(fax)