DSPRelated.com
Forums

Store audio data from DSK6711

Started by naam...@hotmail.com April 9, 2008
Hi guys,
Im implementing noise cancelling in DSK6711 using PCM3003.
Could anyone tell me if there is any way i can store or save my filtered audio speech directly from CCS and not from the PCM3003 output.
Thanks
Nam Nai-

> Im implementing noise cancelling in DSK6711 using PCM3003.
> Could anyone tell me if there is any way i can store or save my
> filtered audio speech directly from CCS and not from the PCM3003
> output.

There are a couple of ways:

1) Use file I/O functions, which will transfer data via CCS + JTAG. This method is slow, and should only be used in
main(), before (or after) real-time code is running.

2) There are free software packages / DLLs out there that will transfer data through the C6711's HPI interface via the
PC parallel port connection. This method is suitable for real-time communication.

-Jeff
Nam Nai-

> Thanks for the help. However, if you could elaborate method number 2, like which
> free software is suitable for my application, it would really help me out.

Here are a couple:

http://www.educationaldsp.com/stockproduct.htm

http://www.signalogic.com/dskc6xxx.htm

I think I've seen others when Googling before, but not sure. Try combining DSK 6711
with keywords like DLL, parallel port, 'real-time data transfer', etc.

-Jeff

> > Date: Wed, 9 Apr 2008 11:28:15 -0500
> > Subject: Re: [audiodsp] Store audio data from DSK6711
> > From: j...@signalogic.com
> > To: n...@hotmail.com
> > CC: a...
> >
> > Nam Nai-
> >
> > > Im implementing noise cancelling in DSK6711 using PCM3003.
> > > Could anyone tell me if there is any way i can store or save my
> > > filtered audio speech directly from CCS and not from the PCM3003
> > > output.
> >
> > There are a couple of ways:
> >
> > 1) Use file I/O functions, which will transfer data via CCS + JTAG. This method
> is slow, and should only be used in
> > main(), before (or after) real-time code is running.
> >
> > 2) There are free software packages / DLLs out there that will transfer data
> through the C6711's HPI interface via the
> > PC parallel port connection. This method is suitable for real-time communication.
> >
> > -Jeff