Dear All, I wonder if we can change the PRD function's parameter dynamically during run-time? Eg. I have a PRD function that predefined using CCS's DSP/BIOS Config tools, named PRD_Example. The "period(ticks)" parameter is set to 1000 (miliseconds). Thus, this PRD_Example will be scheduled to run every 1000 ms. During run-time, can I change the "period" to other values ? How to do that ? Please advice. Thanks!! -- Beh,CS |
|
DSP/BIOS PRD Functions
Started by ●February 28, 2003
Reply by ●February 28, 20032003-02-28
Hi Beh Currently DSP/BIOS does not support changing of period of a PRD object. You can check out if single shot PRD is usefull to solve your case. You can also simulate a variable periodic activity by using TSK_sleep with Mailboxes. Rgds CSR -----Original Message----- From: behcsiang <> [mailto:] Sent: Friday, February 28, 2003 9:18 AM To: Subject: [c6x] DSP/BIOS PRD Functions Dear All, I wonder if we can change the PRD function's parameter dynamically during run-time? Eg. I have a PRD function that predefined using CCS's DSP/BIOS Config tools, named PRD_Example. The "period(ticks)" parameter is set to 1000 (miliseconds). Thus, this PRD_Example will be scheduled to run every 1000 ms. During run-time, can I change the "period" to other values ? How to do that ? Please advice. Thanks!! -- Beh,CS _____________________________________ Note: If you do a simple "reply" with your email client, only the author of this message will receive your answer. You need to do a "reply all" if you want your answer to be distributed to the entire group. _____________________________________ About this discussion group: To Join: Send an email to To Post: Send an email to To Leave: Send an email to Archives: http://www.yahoogroups.com/group/c6x Other Groups: http://www.dsprelated.com ">http://docs.yahoo.com/info/terms/ |