Hi All, I have a problem for initialize McBSP to interface with ST-BUS(4 channels); that is time slot miss-align, two slot are shifted. My McBSP is serviced by EDMA and I've verified that EDMA transfer from DRR is correct but transfer to DXR makes this problem. I've been solving this problem but it still not work correctly. Anyone who have this experience pls help me . Thank you in advance Tumm |
McBSP ,EDMA and ST-BUS on C6711DSK
Started by ●November 25, 2004
Reply by ●November 27, 20042004-11-27
|
Reply by ●November 27, 20042004-11-27
Tumm, Did you have a look at TMS320C6000 McBSP Interface to an ST-BUS Device at http://focus.ti.com/docs/apps/catalog/resources/appnoteabstract.jhtml?abstractNa\ me=spra511b > I have a problem for initialize McBSP to interface with ST-BUS(4 > channels); that is time slot miss-align, two slot are shifted. how did you confirm this. Where did you see the delay?? just on the DX pin of mcbsp?? Tarang > > My McBSP is serviced by EDMA and I've verified that EDMA transfer from > DRR is correct but transfer to DXR makes this problem. I've been solving > this problem but it still not work correctly. Anyone who have this > experience pls help me . > > Thank you in advance > > Tumm > > _____________________________________ > Note: If you do a simple "reply" with your email client, only the author of this message will receive your answer. You need to do a "reply all" if you want your answer to be distributed to the entire group. > > _____________________________________ > About this discussion group: > > To Join: Send an email to > > To Post: Send an email to > > To Leave: Send an email to > > Archives: http://www.yahoogroups.com/group/c6x > > Other Groups: http://www.dsprelated.com > > Yahoo! Groups Links |